| The shape of the 150mm pipework was chosen to trap water in the bottom to prevent the escape of noxious gases. The flow was recorded by a pressure transducer in the 'U' pipe and and compared to an electromagnetic flowmeter in the feed pipe. | The pressure to flow rating function had two modes of operation, here is weir behaviour at low flows. |
|
|
| At high flows, (50L/s) a jet mode was present. | Installation of the pipe flow system. |
|
|
| A completed installation with the pipe outlet and data logger enclosure. | At some sites the council had installed overflow outlets, these could be rated with standard calculations. |
|
|
| At some sites just adding a drain was easier. | The drain pipe in place. |